Skip to content
  • Bernd Flemisch's avatar
    [parallel] perform parallel tests also for UGGrid and ALUGrid · 9bd35010
    Bernd Flemisch authored and Timo Koch's avatar Timo Koch committed
    Also fix the test itself in the following sense. By default, in the
    box method, material law parameters are evaluated at scv centers,
    while primary variables are evaluated at vertices. If no interface
    condition is used, the secondary variables handed to the Vtk
    writer might now differ depending on the order in which the scvs
    are evaluated for each vertex. In order to saty consistent, this
    test evaluates the material law parameters at the vertex position.
    9bd35010