Skip to content

[freeflow] Improve outflow for outflow-tangential velocities

Thomas Fetzer requested to merge freeflow/improveOutflow into master

3: Fuzzy comparison... 3: Comparing /temp/fetzer/dumux-30/dumux/test/references/stokes2c-advection.vtu and /temp/fetzer/dumux-30/dumux/build-gcc/test/freeflow/navierstokesnc/test_advection-00009.vtu 3: ... with a maximum relative error of 0.01 and a maximum absolute error of 1.5e-07*max_abs_parameter_value. 3: 3: Data differs in parameter: velocity_liquid (m/s)_1 3: Difference is too large: 12.07% -> between: 1.9304e-12 and 2.19545e-12 3: Info for velocity_liquid (m/s)_1: max_abs_parameter_value=5.57794e-07 and min_abs_parameter_value=7.82496e-14. 1/1 Test # 3: test_stokes2c_advection ..........***Failed 4.00 sec

5: Fuzzy comparison... 5: Comparing /temp/fetzer/dumux-30/dumux/test/references/stokes2cni-diffusion.vtu and /temp/fetzer/dumux-30/dumux/build-gcc/test/freeflow/navierstokesnc/test_stokes2cni_diffusion-00014.vtu 5: ... with a maximum relative error of 0.01 and a maximum absolute error of 1.5e-07*max_abs_parameter_value. 5: 5: Data differs in parameter: velocity_liquid (m/s)_1 5: Difference is too large: 11.03% -> between: 3.58003e-16 and 3.18503e-16 5: Info for velocity_liquid (m/s)_1: max_abs_parameter_value=2.59526e-15 and min_abs_parameter_value=2.41857e-17. 1/1 Test # 5: test_stokes2cni_diffusion ........***Failed 3.30 sec

2: Fuzzy comparison... 2: Comparing /temp/fetzer/dumux-30/dumux/test/references/test_channel_zeroeq2cni.vtu and /temp/fetzer/dumux-30/dumux/build-gcc/test/freeflow/ransnc/test_channel2cni-00034.vtu 2: ... with a maximum relative error of 0.01 and a maximum absolute error of 1.5e-07*max_abs_parameter_value. 2: 2: Data differs in parameter: dv_y/dx__0 2: Difference is too large: 1.98% -> between: 8.98301e-07 and 9.16448e-07 2: Info for dv_y/dx__0: max_abs_parameter_value=0.00165376 and min_abs_parameter_value=6.00311e-10. 2: 2: Data differs in parameter: dv_y/dx__1 2: Difference is too large: 18.65% -> between: 9.50107e-07 and 1.16791e-06 2: Info for dv_y/dx__1: max_abs_parameter_value=0.17919 and min_abs_parameter_value=7.97612e-07. 2: 2: Data differs in parameter: velocity_gas (m/s)_1 2: Difference is too large: 1.06% -> between: -2.07522e-06 and -2.05331e-06 2: Info for velocity_gas (m/s)_1: max_abs_parameter_value=0.00236756 and min_abs_parameter_value=9.67192e-11. 1/1 Test # 2: test_channel_zeroeq2cni ..........***Failed 8.41 sec

the fourth test was in a similar range

Edited by Thomas Fetzer

Merge request reports